Health Post Building | Fujel SHP

GENERAL BUILDING DETAILS
Name Health Post Building
Purpose Health Post Building
Plot Number 294,295
Damage Status Partially Damaged ( Load Bearing Wall - repairable )
Ground Coverage 637.56 ft2
ADDITIONAL INFRASTRUCTURAL DETAILS
Year of Construction 2054
Ground Coverage 637.56
Number of Storeys 1
Type of Structure Load Bearing (Stone)
Mortar Type Mud Mortar
Does building have seismic elements? NO
Type of Roof UPVC
Type of Floor Pcc
Door/Window Type Wooden
INFRASTRUCTURAL DAMAGE DETAILS
Damage to Door/Windows 50% - 100%
Large cracks in the ground nearby NO
Retaining Wall Status Not Applicable
Overall Hazards Damage Level
Collapse or Partial Collapse E1
Building or storey leaning ND
Structural Hazards Damage Level
Foundation ND
Roof ND
Floor M2
For Load Bearing Buildings Damage Level
Corner Separation E1
Diagonal Cracking ND
Out Of Plane Failure ND
In Plane Failure ND
Delamination ND
Nonstructural Hazards Damage Level
Parapets ND
Cladding, glazing ND
Ceilings ND
Interior walls, Partitions E1
Geotechnical Hazards Damage Level
Slope failure, debris ND
Ground Movement ND
Mortar Strength Test - Scratching with: Damage Level
Fingernail Heavily Scratched
Aluminum Nail Heavily Scratched
Iron Nail Heavily Scratched
Type of Crack Found (CLICK HERE FOR LEGEND) Length
Crack Number 1 1 m
Crack Number 7 16 m
Crack Number 11 10 m
BUILDING LAYOUT SKETCH
Sketch - Fujel SHP-Health Post Building
BUILDING PICTURES
Health Post Building
BUILDING DAMAGE PICTURES
Health Post Building
Health Post Building
Health Post Building
Health Post Building
TYPICAL CRACK PICTURES
Health Post Building
Health Post Building
Health Post Building